No Özeti sayfasında içerik 1

®SSC200Solid State Rate/Gyro CompassUser’s ManualRevision 1.8Copyright © 2012 Maretron, LLP All Rights ReservedMaretron, LLP9014 N. 23rd Ave #10Phoenix, AZ 85021-7850http://www.maretron.comMaretron Manual Part #: M000401Revision 1.8Page i

No Özeti sayfasında içerik 2

SSC200 User’s ManualRevision HistoryRevisionDescription1.0Original document.1.1Minor editorial changes.Corrected default rate for Rate of Turn PGN under Technical Specifications.1.2Minor editorial changes.Removed Warranty Card.1.3Changed copyright to 2005.Added text to describe new feature (programmable variation) under Section 1.2,3.0, 3.3, and Appendix B.1.4Added Variation section.Added Rate of Turn section.Updated Appendix A Maretron Proprietary Execute Sentence definitions.Updated Appendix

No Özeti sayfasında içerik 3

®Table of Contents1 2 3 4 5 6 7 8 9 10 11 General ..............................................................................................................................1 1.1  Introduction ................................................................................................................1 1.2  Firmware Revision .....................................................................................................1 1.3  Features ................................

No Özeti sayfasında içerik 4

SSC200 User’s ManualTable of FiguresFigure 1 – Mounting the SSC200 to a Horizontal Surface ......................................................... 4Figure 2 – Mounting the SSC200 to Vertical Surface ................................................................ 5Figure 3 – NMEA 2000® / NMEA 0183 Interface Connector Locations ..................................... 6Figure 4 – NMEA 2000®/Power Connector Face Views ............................................................ 6Figure

No Özeti sayfasında içerik 5

®1 General1.1 IntroductionCongratulations on your purchase of the Maretron SSC200 Solid State Rate/Gyro Compass.Maretron has designed and built your compass to the highest standards for years of reliable,dependable, and accurate service.The SSC200 detects the direction of the earth’s magnetic field using solid statemagnetometers and indicates the vessel heading relative to magnetic north. In addition, theSSC200 incorporates solid state accelerometers and a solid state angular rate sensor fori

No Özeti sayfasında içerik 6

SSC200 User’s Manual6. Calibrate the SSC200 Compass for Installation-Offset (Section 3.2)7. Use Default Variation Source or Select an Appropriate Variation Source (Section 4)2 Installation2.1 Unpacking the BoxWhen unpacking the box containing the Maretron SSC200, you should find the following items.••••••••1 - SSC200 Solid State Compass2 - Mounting Brackets4 - Mounting Bracket Screws4 - Mounting Screws1 - 10 meter NMEA 0183 Cable*1 - NMEA 2000® Micro Field Attachable Connector

No Özeti sayfasında içerik 7

®switched on and off, which makes compensation impractical. Therefore, you should try tomount the compass as far away as possible from these magnetic field sources (doubling thedistance between the magnetic field source and the compass will reduce the field strengthby a factor of approximately 8). Also, always observe any “compass-safe distance” markingson other electronic equipment.6. Minimal Vibration – Although the SSC200 is more tolerant of vibration than a fluxgatecompass, it is best

No Özeti sayfasında içerik 8

SSC200 User’s ManualFigure 1 – Mounting the SSC200 to a Horizontal Surface2.3.2 Mounting the SSC200 to a Vertical SurfaceMounting the SSC200 compass to a vertical surface requires that the provided mountingbrackets be fastened to the side of the SSC200 using the provided brass flat head screws.Once the mounting brackets are securely fastened to the side of the SSC200, attach theSSC200 securely to the vessel using the included brass mounting screws or other non-ferrousfasteners as shown in Fi

No Özeti sayfasında içerik 9

®Figure 2 – Mounting the SSC200 to Vertical Surface2.4 Connecting the SSC200You have a choice of connecting the SSC200 to a NMEA 2000® interface (Section 2.4.1),NMEA 0183 interface (Section 2.4.2), or connecting both interfaces simultaneously (Section2.4.2.2).Revision 1.8Page 5

No Özeti sayfasında içerik 10

SSC200 User’s ManualNMEA 2000 / PowerConnectorNMEA 0183 ConnectorFigure 3 – NMEA 2000® / NMEA 0183 Interface Connector Locations2.4.1 Connecting to NMEA 2000® InterfaceThe Maretron SSC200 provides a connection to an NMEA 2000® interface through a five pinmale connector (Figure 4). You connect the SSC200 to an NMEA 2000® network using aMaretron NMEA 2000® cable (or compatible cable) by connecting the female end of the cableto the SSC200 (note the key on the male connector and keyway on t

No Özeti sayfasında içerik 11

®Figure 5 - SSC200 with NMEA 2000® Connection Only2.4.2 Connecting to NMEA 0183 InterfaceThe Maretron SSC200 provides a connection to an NMEA 0183 interface through an eight pinmale connector (Figure 6). You connect the SSC200 to an NMEA 0183 network using theMaretron supplied 10 meter cable by connecting the female end of the cable to the SSC200(note the key on the male connector and keyway on the female connector). Be sure the cableis connected securely and that the collar on the cable conne

No Özeti sayfasında içerik 12

SSC200 User’s ManualFigure 6 – NMEA 0183 Connector Face ViewsConnect the other end of the cable consisting of individual wires using recommended practicesfor installing NMEA 0183 products. Please note that NMEA 0183 does not have a standard forconnectors and the customer/installer should contact the manufacturer of the equipment towhich the SSC200 is being connected for information on how to properly connect the device tothe SSC200. The individual wires found within the cable have the follow

No Özeti sayfasında içerik 13

®Figure 8 - SSC200 with NMEA 0183 Connection Only2.4.2.2Supported NMEA 0183 Baud RatesThe SSC200 compass supports NMEA0183 communication at both 4800 baud and 38400baud. All SSC200 Compasses are shipped with a baud rate of 4800 baud. The baud rate maybe set to 38400 baud by connecting to the compass using a teminal emulator (See Appendix Cfor details) and sending the following strings to the compass through the NMEA 0183connection:shellThis will cause the “cmd>” command prompt to be display

No Özeti sayfasında içerik 14

SSC200 User’s ManualThis causes the new baud rate to be stored to non-volatile memory, so the compass will retainthis baud rate when it is powered down.2.4.3 Connecting Both NMEA 2000® and NMEA 0183 InterfacesThe SSC200 can be simultaneously connected to both an NMEA 2000® network and an NMEA0183 network.2.4.4 Checking ConnectionsOnce the NMEA 2000®/Power and/or NMEA 0183 connections to the Maretron SSC200 havebeen completed, check to see that heading information is being properly transmitt

No Özeti sayfasında içerik 15

®values in its permanent memory. Therefore, it is important to verify that the deviationcalibration process completed successfully.The preferred method for deviation calibration is to use a Maretron display (procedure 1)because you receive direct feedback on the calibration process with a clear indication of asuccessful or unsuccessful deviation calibration. Deviation calibration done automatically atpower-up (procedure 2) is less desirable than procedure 1 because it is more difficult to verif

No Özeti sayfasında içerik 16

SSC200 User’s Manual4. While continuing to turn the vessel as indicated in step 3, remove the power from thecompass and reapply power (this initiates deviation calibration).5. Continue turning the vessel through four complete circles in less than 10 minutes fromthe time power was applied.6. Successful deviation is indicated when the SSC200 outputs the following sequence:a) 0 Degrees for two seconds followed byb) 90 degrees for two seconds followed byc) 180 degrees for two seconds followed byd)

No Özeti sayfasında içerik 17

®2. With the vessel laying flat in the water, adjust the pitch angle of the SSC200 by addingsmall washers or spacers between the mounting bracket holes and mounting surfaceuntil the display reads zero for the pitch angle (skip this step if you are not interested inviewing the vessel’s pitch angle).3. With the vessel laying flat in the water on a known heading, adjust the heading of theSSC200 by rotating it until the display reads the known vessel heading.4. Recheck that the roll and pitch rea

No Özeti sayfasında içerik 18

SSC200 User’s Manual1. Transmit the Heading, Deviation & Variation (HDG) sentence including the variationfield as seen from the RMC or VTG sentence over the NMEA 0183 interface if HDG isenabled (see Appendix A for enabling or disabling NMEA 0183 sentences).2. Transmit the Heading True (HDT) sentence using variation data from the RMC or VTGsentence over the NMEA 0183 interface if HDT is enabled (see Appendix A for enablingor disabling NMEA 0183 sentences).3. Transmit over the NMEA 2000® interf

No Özeti sayfasında içerik 19

®4.4 Variation Source SelectionAs shipped from the factory, the SSC200 automatically looks for variation from both the NMEA0183 and NMEA 2000® interfaces. If there is only a single source of variation available (eitherfrom the NMEA 0183 or the NMEA 2000® interface), then there is no need to manually select avariation source. However, if there are multiple variation sources (i.e., variation available fromboth the NMEA 0183 and NMEA 2000® interfaces) or there is no source for variation (i.e.,v

No Özeti sayfasında içerik 20

SSC200 User’s Manual5.1 Rate of Turn Damping Period Selection with Maretron DisplayYou can program the SSC200 to use a particular rate of turn damping period using a Maretrondisplay product (e.g., DSM200). Refer to the display product user’s manual for details onprogramming the SSC200 to use a specific damping period.5.2 Rate of Turn Damping Period Selection by NMEA 0183InterfaceYou can program the SSC200 to use a particular rate of turn damping period through theNMEA 0183 interface. Refer t