Olympus 2 0 0 8 – 1 0 Camera Lens Kullanım Kılavuzu

Kullanım Kılavuzu için aygıtı Olympus 2 0 0 8 – 1 0 Camera Lens

Olympus 2 0 0 8 – 1 0 Camera Lens Kullanım Kılavuzu

İçeriğini ayıklar

No Özeti sayfasında içerik 1

MICROSCOPECOMPONENTS GUIDEChoosing The Ideal UIS2 Optics Components For Your Equipment2008-10

No Özeti sayfasında içerik 2

The wide range of Olympus components introduced hereallows users in such diverse fields as research, inspection and productionto take advantage of the quality, flexibility andoutstanding optical performance of the UIS2 Optical System.That's why installing Olympus microscope components is,quite simply, the right choice for your equipment.1

No Özeti sayfasında içerik 3

CONTENTSWELCOME TO UIS2/UIS OPTICS ---------------------------------------------- 3 — 4EYEPIECES/FILAR MICROMETER EYEPIECE --------------------------------- 33Widefield eyepiecesSYSTEM DIAGRAM --------------------------------------------------------------- 5 — 6Super widefield eyepiecesFilar micrometer eyepieceUIS2/UIS OBJECTIVE LENSES ----------------------------------------------- 7 — 18NEWM Plan ApochromatMPLAPON series -------------------------------8M Plan SemiApochromatMPLFLN series

No Özeti sayfasında içerik 4

WELCOME TO UIS2/UIS OPTICSUIS2/UIS:The System That Maximizes The Advantage Of Infinity-Corrected OpticsWhat's infinity-corrected optics?light between the objective lens and tube lens,allowing the creation of user-specific or taskspecific optical systems. To establish real flexibilitywith such a system, it is necessary to eliminate theoccurrence of coma aberration.UIS2/UIS optics is an infinity-corrected opticalsystem — in other words, a system in which lightpasses from the specimen through the

No Özeti sayfasında içerik 5

WELCOME TO UIS2/UIS OPTICSFeatures of UIS2 objective lenses4. LighteningWeight has been reduced to approximately 2/3that of conventional products by using analuminum objective lens barrel cover. This hasthe effect of lightening the load on the devices atobjective lens up/down, suppressing vibrationsby lowering the inertial force at objective lensswitching, etc. (MPLFLN series, LMPLFLNseries)UIS2 objective lenses ensure compatibility (screwdiameter, optical performance) with the UIS opticalsystem

No Özeti sayfasında içerik 6

SYSTEM DIAGRAMBXFM SYSTEM DIAGRAMVideo systemRefer to pages 36-37Video cameraVideo cameraC-mountB mount 2/3"Video cameraS mount 2/3"Video cameraF mountU-FMTU-CMAD3U-BMADU-SMADU-TMADU-TV0.25xCU-TV0.35xC-2U-TV0.5xC-3U-TV0.63xCU-TV1x-2Observation/single tubesand eyepiecesRefer to pages 29-30WHNEyepiecesWidefield trinocularobservation tubesSWHEyepiecesSuper widefield trinocularobservation tubesU-TLUU-TLUIRIllumination systems and power supplyU-AN360-3U-AN360IRU-ANU-PO3U-POIRU-25ND6, U-25ND25,U-25LBD

No Özeti sayfasında içerik 7

SYSTEM DIAGRAMMOTORIZED UNIT SYSTEM DIAGRAMRefer to pages 38-40Observation tubes(Refer to pages 29-30)U-ANU-ANMX-AFDICU-AN360-3Intermediate tubes(Refer to pages 31-32)U-FWORefer to page 26U-PO3U-AFA2M-VISU-LH75XEAPOU-LH100HGAPOU-LH100HGU-POTP3U-25ND6,U-25ND25U-25LBDU-25IF550U-25L42U-25FRMirror unitsU-LH100-3U-LH100L-3U-FWRBX-RLAABX-RFAAU-ZPCBZ boardBX-UCB*U-DICRU-D6REMCRefer topage 35Refer to pages 7-18See manualU-HSTR2BF objective lensesU-DICRHBD-M-ADU-D5BDREMCU-D6BDREMCU-DICRHCPCBF/DF objectiv

No Özeti sayfasında içerik 8

UIS2/UIS OBJECTIVE LENSES■ Meaning of abbreviations shown on objective lensM P L (Plan) F L N - 1 0 0M:LM:Metallurgical (no cover)Long working distancemetallurgical useSLM: Super long workingdistance metallurgical useLC: Observation throughsubstratePL: Plan/Corrects fieldcurvature ofthe periphery ofthe image plane■ Objective lens notationNone: Achromat/Corrects aberration at 2 wavelengths ofblue and redFL:SemiApochromat/Corrects chromatic aberration in thevisible range (violet~red)APO: Apoch

No Özeti sayfasında içerik 9

UIS2 OBJECTIVE LENSESPlan ApochromatMPLAPON seriesPlan Apochromat objective lenses that correct chromatic aberrations at the highest level.Olympus guarantees*1 optical performance (wavefront aberration) with a Strehl ratio*2 of 95% or better.They are also designed for use with Olympus' U-AFA2M active AF unit.MPLAPON100xø20.32ø20.32ø8.8ø5.5ø16WD=0.35WD=0.35ø18.9ø20.3ø28.5ø20.2MPLAPON 50xMPLAPON 100xNumericalAperture0.950.95Widefield eyepiece WHN10xField Number 22Working distance Focal di

No Özeti sayfasında içerik 10

UIS2 OBJECTIVE LENSESM Plan SemiApochromatMPLFLN seriesPlan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The lineup consists of 7 objectivelenses ranging from 1.25x to 100x, and secures a W.D. of 1mm or longer. Since the exit pupil position of the 5x-100x objectivelenses is standardized, the position of the DIC prism does not have to be switched when changing the magnification.For ultra low magnifications (1.25x, 2.5x), use together with analyzer and po

No Özeti sayfasında içerik 11

UIS2 OBJECTIVE LENSESLong WD M Plan SemiApochromat(WD: Working Distance)LMPLFLN seriesLong working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.Suitable with samples having a height difference and in preventing collision, as the working distance is long.Also, since the exit pupil position of the 5x-100x objective lenses is standardized, the position of the DIC prism does not haveto be switched when changing the magnification.LMPLFLN10xLMPLF

No Özeti sayfasında içerik 12

UIS2 OBJECTIVE LENSESM Plan AchromatMPLN seriesPlan Achromat objective lenses providing excellent image flatness up to F.N. 22.MPLN10xMPLN20xø20.32ø20.32ø20.3241.337.2ø6ø11.9ø16ø15.8ø24ø24MPLN50xMPLN100xø20.32ø20.3238.742.843.1645ø15.8WD=0.21ø6ø11.9(44.79)37.241.342.62(44.62)4.54.542.445ø12WD=1.3ø24(43.7)28.833.632.714.5WD=10.6WD=20(34.4)4523.44.5(25)45ø10.5ø21WD=0.38454.5MPLN5xø4.4ø11.6ø15.6ø24ø24Unit: mmWidefield eyepiece WHN10xField Number 22UIS2 objective lensesObjecti

No Özeti sayfasında içerik 13

UIS2 OBJECTIVE LENSESLCD Long WD M Plan SemiApochromatLCPLFLN-LCD seriesPerfect objective lens series for observation of LCD panels and other samples through a glass substrate.Aberration correction matched to the glass thickness is accomplished using a correction ring.LCPLFLN50xLCD***LCPLFLN100xLCD***ø20.32ø20.32ø20.322027.5ø17.84ø25ø31ø15.2WD=0.9ø29.5t=0.7WD=2.5t=0.7ø25ø25t=0.741.643.445.238 *(43.638)2538.6540.45(42.038)45.238 *ø12.77ø15WD=7.8204.82024.534.7536.554.5(36.738)45.238 *

No Özeti sayfasında içerik 14

UIS2 OBJECTIVE LENSESSuper Long WD M Plan AchromatSLMPLN seriesPlan Achromat objective lenses with high magnification and super long working distance.Three magnifications, 20x, 50x and 100x are available. For 5x or 10x objective lenses, select from the LMPLFLN series.SLMPLN20xSLMPLN50xø20.32SLMPLN100x36.237.2(37.4)24.14545ø16.9ø14.7ø25ø17.3ø23.8ø26WD=7.6ø16.1WD=18WD=25(27)26.319.319.845(20)4.9ø20.324.94.9ø20.32ø21.4ø26ø26Unit: mmUIS2 objective lensesObjective lens(magnification)Nume

No Özeti sayfasında içerik 15

UIS OBJECTIVE LENSESIR Long WD M Plan Achromat/IR M Plan AchromatLMPlan-IR series/MPlan-IRUNIVERSALINFINITY SYSTEMIR objective lenses which compensate for aberrations from visible to near infrared light.Ideal for the observations of semiconductor interiors and the back surface of a chip package as well as CSP bump inspection.LMPlan5xIRLMPlan10xIRLMPlan20xIRø20.3230.334.34.54545(36.9)4.5ø20.32(26.5)252322.545(25)4.5ø20.32WD=8.1ø26ø10.4ø12.4WD=18.5WD=20ø21ø15ø22ø18ø26ø26LMPlan100xIRMPl

No Özeti sayfasında içerik 16

UIS2 OBJECTIVE LENSESM Plan SemiApochromat BD(BD:Brightfield/Darkfield)MPLFLN-BD seriesPlan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.The series secures a W.D. of 1mm or longer. Since the exit pupil position of the 5x-150x objective lenses is standardized, theposition of the DIC prism does not have to be switched when changing the magnification.MPLFLN10xBDMPLFLN20xBDø26ø26ø26ø22ø26.2ø3235.973939.5ø22ø27.5ø27ø28.5ø32ø32MPLFLN50xBDMPLFLN100x

No Özeti sayfasında içerik 17

UIS2 OBJECTIVE LENSESM Plan SemiApochromat BDP(BDP:Brightfield/Darkfield/Polarizing)MPLFLN-BDP seriesPlan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The series secures a W.D. of1mm or longer. Since the exit pupil position of the 5x-100x objective lenses is standardized, the position of the DIC prismdoes not have to be switched when changing the magnification. The BDP series optimizing brightfield/darkfield and polarizedlight characteristics is perfect

No Özeti sayfasında içerik 18

UIS2 OBJECTIVE LENSESLong WD M Plan SemiApochromat BDLMPLFLN-BD seriesLong working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration.Suitable with samples having a height difference and in preventing collision, as the working distance is long.Also, since the exit pupil position of the 5x-100x objective lenses is standardized, the position of the DIC prism does not haveto be switched when changing the magnification.LMPLFLN10xBDLMPLFLN20xBDø26ø2

No Özeti sayfasında içerik 19

UIS2 OBJECTIVE LENSESM Plan Achromat BDMPLN-BD seriesPlan Achromat objective lenses providing excellent image flatness up to F.N. 22.MPLN10xBDø26ø26MPLN20xBDø26ø30.541ø17WD=1.3WD=6.5ø16.8ø29.3WD=1242.545ø16(43.7)34.013736.545(38.5)3130.2531.545(33)4.54.5(4.5)MPLN5xBDø22ø26ø32ø23.6ø29ø27ø32ø32MPLN100xBDø26ø264142.543.3343.7145(44.79)4142.543.6845(44.62)4.54.5MPLN50xBDø10ø23.1WD=0.21WD=0.38ø10ø20.7ø23ø27ø29ø29ø32ø32Unit: mmWidefield eyepiece WHN10xField Number 22UIS2 ob

No Özeti sayfasında içerik 20

MICROSCOPE SYSTEM BXFMBXFM frameBXFM-FWidely used system that allows use in combination with fiber illumination, motorized revolving nosepiece and telan lens unit.Can easily be integrated into other equipment. Attach to the equipment by rear bolt mounting screw or pillar mounting hole.8436824–M4 depth9(13)Stroke350.50.54–M4 depth766.21617Pillar mount hole center(13)1780551241001734234-M8 depth8(Bolt mount screw)758.5362A00002ø32H(Pi 8llarmoun98thWeight: 1.9kg19ole)110Unit: mm